>>> b dkb400
-DKB400
Ultrixboot - V4.2 Tue Mar 19 02:16:58 EST 1991
Loading (a)vmunix ...
Sizes:
text = 826312
data = 1268224
bss = 691656
Starting at 0x5201
ULTRIX V4.2 (Rev. 85) System #1: Tue Mar 19 01:50:03 EST 1991
real mem = 12468224
avail mem = 7962624
Buffer configuration adjusted to run with small system page table
using 276 buffers containing 1246208 bytes of memory
KA41-A/B with an FPU
scsi0 at uba0 csr 0x200c0080 vec 0x1f8, ipl 0x14
rz0 at scsi0 slave 0 (RZ23L)
scsi1 at uba0 csr 0x200c0180 vec 0x1fc, ipl 0x14
rz12 at scsi1 slave 4 (RZxx)
ss0 at uba0 csr 0x200a0000 vec 0xc0, ipl 0x14
NO LOOPBACK
WARNING: clock lost 8 days -- CHECK AND RESET THE DATE!
*** STANDALONE ULTRIX ENVIRONMENT ***
If you select the BASIC Installation option from the list that follows,
the installation software creates file systems on default partitions on
your system disk and loads the mandatory ULTRIX software subsets.
If you require additional installation choices, select the ADVANCED
Installation option.
Select one of the following options:
1) BASIC Installation
2) ADVANCED Installation
3) System management
Enter your choice: 1
*** SYSTEM DISK SELECTION ***
The 'Guide to Installing ULTRIX' explains the following table
of system disk drives. Select one of the devices below to contain the
root file system:
SYSTEM DISK TABLE
Selection Device ULTRIX Device Controller Controller
Name Name Number Name Number
----------------------------------------------------------------------
1 RZ23L rz0 0 VS_SCSI 0
2 RZxx rz12 4 VS_SCSI 1
----------------------------------------------------------------------
Enter your choice: 1
You selected RZ23L, device number 0. Make sure this disk drive
is on line and write-enabled (if applicable to your disk drive), then
confirm your choice.
Use RZ23L, rz0, for your system disk? (y/n) []: yx\x/
NOTE: The RZ23L disk is not supported by itself as a system disk.
A second suitably sized disk is required to perform the installation.
Disk partitions must be carefully selected based on the usage infor-
mation in the Guide to Installing ULTRIX.
BASIC installations are not allowed using the RZ23L as a system
disk. The installation procedure will switch to ADVANCED installation
and continue.
The installation procedure now allocates the root file system on
partition 'a' of the system disk, rz0 RZ23L.
Making the root file system on rz0 RZ23L.
The installation procedure is now restoring the root file system to
partition 'a' of the system disk, rz0 RZ23L.
The installation procedure now checks the root file system on partition 'a'
of the system disk, rz0 RZ23L.
** /dev/rrz0a
** Last Mounted on /mnt
** Phase 1 - Check Blocks and Sizes
** Phase 2 - Check Pathnames
** Phase 3 - Check Connectivity
** Phase 4 - Check Reference Counts
** Phase 5 - Check Cyl groups
226 files, 6470 used, 8889 free (49 frags, 1105 blocks, 0.3% fragmentation)
*** BOOTSTRAP COMMAND SEQUENCE ***
Enter the following boot sequence at the console mode prompt
after the installation software halts the processor:
>>> b dka000
syncing disks... done
?06 HLT INST
PC = 80068FF9
>>> b dka0
-DKA0
Ultrixboot - V4.2 Tue Mar 19 02:16:58 EST 1991
Loading (a)vmunix ...
Sizes:
text = 1092572
data = 262144
bss = 1020548
Starting at 0x5201
ULTRIX V4.2 (Rev. 85) System #1: Tue Mar 19 01:13:29 EST 1991
real mem = 12468224
avail mem = 8327168
Buffer configuration adjusted to run with small system page table
using 261 buffers containing 1246208 bytes of memory
KA41-A/B with an FPU
scsi0 at uba0 csr 0x200c0080 vec 0x1f8, ipl 0x14
rz0 at scsi0 slave 0 (RZ23L)
scsi1 at uba0 csr 0x200c0180 vec 0x1fc, ipl 0x14
rz12 at scsi1 slave 4 (RZxx)
ss0 at uba0 csr 0x200a0000 vec 0xc0, ipl 0x14
sh0 at uba0 csr 0x38000000 vec 0x44, ipl 0x14
ln0 at ibus0 csr 0x200e0000 vec 0x50, ipl 0x14
ln0: DEC LANCE Ethernet Interface, hardware address: 08:00:2b:27:da:a1
*** SYSTEM NAME SPECIFICATION ***
Select the name of your system using alphanumeric characters.
The first character must be a letter. For example, tinker.
Enter your system name: vax3100
You selected vax3100 as the name of your system.
Is this correct? (y/n) [y]: y
*** DATE AND TIME SPECIFICATION ***
The current date and time should be specified using the following
format:
yymmddhhmm
Use two digits for year (yy), month (mm), day (dd), hour (hh), and
minute (mm). Enter the time in 24-hour format. For example, 11:30
p.m. on May 3, 1991 would be entered as:
9105032330
Enter the date and time: 9503101911
*** TIME ZONE SELECTION ***
Select the time zone for your area, using the options listed in the
table below. You can also enter the number of hours (-12 to 12) in
time east of Greenwich.
Selection Time Zone
---------------------------------
e Eastern
c Central
m Mountain
p Pacific
g Greenwich
---------------------------------
Enter your choice: g
Does your area alternate between Daylight Savings and Standard
time? (y/n) [y]:
Select your geographic area for Daylight Savings Time, using the
options in the table below.
Selection Geographic Area
--------------------------------
u USA
a Australia
e Eastern Europe
c Central Europe
w Western Europe
--------------------------------
Enter your choice [u]: c
The current date and time is Fri Mar 10 19:11:10 EST 1995
*** SPECIFY THE SUPERUSER PASSWORD ***
The Guide to Installing ULTRIX instructs you on how to enter
the superuser password.
Changing password for root
Enter new password:
Verify:
*** FILE SYSTEM DEFAULT OPTION ***
The following table shows the default file system layout on RZ23L, rz0:
partition bottom top size overlap default
a 0 32767 32768 c root
b 32768 99457 66690 c swap, dump
g 99458 237587 138130 c,d,e,f,h /usr
If you choose the defaults, the var area will be allocated to /usr/var.
Do you want to choose the default file system layout? (y/n): y
Making the new file system for /usr on /dev/rrz0g RZ23L
This distribution media includes subsets for ULTRIX Worksystem
Software (UWS). A UWS license (on a workstation) or a UWS Server
License (on a timesharing machine or server) is required to install
these subsets.
Do you want to install ULTRIX Worksystem Software? y/n []: n
*** SUPPORTED SOFTWARE INSTALLATION ***
*** Enter Subset Selections ***
The following subsets are mandatory and will be installed automatically:
* Base System * Kernel Configuration Files
* TCP/IP Networking Utilities * Network File System Utilities
* Extended (Berkeley) Mailer
The subsets listed below are optional:
1) Printer Support Environment 2) Accounting Software
3) Software Development Utilities 4) Internationalization Runtime Env.
5) Internationalization Dev. Env. 6) CDA Base System
7) CDA Software Dev Libraries 8) Source Code Control System
9) Pascal Development Package 10) Doc. Preparation for Ref. Pages
11) Other Doc. Preparation Software 12) Adobe Font Metric Files
13) RAND Mail Handler 14) Communications Utilities
15) RPC Runtime Environment 16) RPC Development Environment
17) Kerberos Network Authentication 18) Enhanced Security Features
19) Sys. Config. Mgmt. Program (SCAMP) 20) Prestoserve Utilities
21) Maintenance Operations Protocol 22) Unix-to-Unix Copy Facility
23) VAX C/ULTRIX 24) System Exerciser Package
25) Bisynchronous Communications 26) Ref. Pages for Sys. Admin. & Users
27) Reference Pages for Programmers 28) Programming Examples
29) All of the Above
30) None of the Above
31) Exit without installing subsets
Enter your choice(s): 30
You are installing the following subsets:
Base System Kernel Configuration Files
TCP/IP Networking Utilities Network File System Utilities
Extended (Berkeley) Mailer
Is this correct? (y/n): y
Base System (ULTBASE420)
Copying from /mnt/VAX/BASE (disk)
Working....Fri Mar 10 19:21:16 EST 1995
Working....Fri Mar 10 19:23:32 EST 1995
Working....Fri Mar 10 19:25:39 EST 1995
Verifying
Working....Fri Mar 10 19:26:26 EST 1995
Kernel Configuration Files (ULTBIN420)
Copying from /mnt/VAX/BASE (disk)
Working....Fri Mar 10 19:28:08 EST 1995
Working....Fri Mar 10 19:30:21 EST 1995
Verifying
Working....Fri Mar 10 19:31:44 EST 1995
TCP/IP Networking Utilities (ULTINET420)
Copying from /mnt/VAX/BASE (disk)
stdin: not in compressed format
tar: blocksize = 0
Verifying
setld:
There were verification errors for TCP/IP Networking Utilities (ULTINET420)
The installation software was unable to install the supported software
subsets.
*** Attempting again to install the supported software subsets. ***
*** Enter Subset Selections ***
The following subsets are mandatory and will be installed automatically:
* TCP/IP Networking Utilities * Network File System Utilities
* Extended (Berkeley) Mailer
The subsets listed below are optional:
1) Printer Support Environment 2) Accounting Software
3) Software Development Utilities 4) Internationalization Runtime Env.
5) Internationalization Dev. Env. 6) CDA Base System
7) CDA Software Dev Libraries 8) Source Code Control System
9) Pascal Development Package 10) Doc. Preparation for Ref. Pages
11) Other Doc. Preparation Software 12) Adobe Font Metric Files
13) RAND Mail Handler 14) Communications Utilities
15) RPC Runtime Environment 16) RPC Development Environment
17) Kerberos Network Authentication 18) Enhanced Security Features
19) Sys. Config. Mgmt. Program (SCAMP) 20) Prestoserve Utilities
21) Maintenance Operations Protocol 22) Unix-to-Unix Copy Facility
23) VAX C/ULTRIX 24) System Exerciser Package
25) Bisynchronous Communications 26) Ref. Pages for Sys. Admin. & Users
27) Reference Pages for Programmers 28) Programming Examples
29) All of the Above
30) None of the Above
31) Exit without installing subsets
Enter your choice(s):
Post Views: 268