{"id":1635,"date":"2018-01-21T13:15:35","date_gmt":"2018-01-21T12:15:35","guid":{"rendered":"http:\/\/www.pdp-11.de\/?page_id=1635"},"modified":"2018-01-21T17:53:41","modified_gmt":"2018-01-21T16:53:41","slug":"dec-rd54-maxtor-xt2190","status":"publish","type":"page","link":"https:\/\/www.pdp-11.de\/index.php\/dec-devices\/dec-rd54-maxtor-xt2190\/","title":{"rendered":"DEC RD54 (Maxtor XT2190)"},"content":{"rendered":"<p>Today I have reviewed a part of my DEC RD54 Drives, and have started to inventory and Format them, to see if they are still in working condition.<\/p>\n<p>I use always my MVII with an RQDX3 Controller and the DEC MDM Diagnostics. (not the Customer version)<\/p>\n<p>You can also use a MicroVAX2000, as he has an Formatter integrated in the PROM, and is from this point a good tool for this job.<\/p>\n<p>Tests were done with the MDM tools in version 4.8 via TK50.<\/p>\n<p>&nbsp;<\/p>\n<h3>1. Disk<\/h3>\n<pre>&gt;&gt;&gt; b mua0\r\n\r\n2..1..0..\r\n\r\nuVDOS V4.0 built on 21-apr-1992 12:01\r\n\r\nMicroVAX Diagnostic Monitor Release 137 Version V4.8\r\n\r\nCONFIDENTIAL DIAGNOSTIC SOFTWARE\r\n PROPERTY OF\r\n DIGITAL EQUIPMENT CORPORATION\r\n\r\nUse Authorized Only Pursuant to a Valid Right-to-use License\r\n\r\nCopyright (c) 1986, 1992\r\n Digital Equipment Corporation\r\n\r\nThe current date and time is: 19-JAN-1997 12:37:56.32\r\n\r\nPress the RETURN key to continue,\r\n or enter the new date and time; then press the RETURN key.\r\n\r\n[DD-MMM-YYYY HH:MM]: 21-jan-1997 12:34\r\n\r\nThe current date and time is: 21-JAN-1997 12:34:28.01\r\n\r\nDo you want to use Menu Mode or Command Line Mode?\r\n\r\n1 - Menu Mode\r\n 2 - Command Line Mode\r\n\r\nType the number; then press the RETURN key. &gt; 1\r\n MAIN MENU Release 137 Version V4.8\r\n\r\n1 - Test the system\r\n\r\n\r\n 2 - Display System Configuration and Devices\r\n\r\n\r\n 3 - Display the System Utilities Menu\r\n\r\n\r\n 4 - Display the Service Menu\r\n\r\n\r\n 5 - Display the Connect\/Ignore Menu\r\n\r\n\r\n 6 - Select single device tests\r\n\r\n\r\n Type the number; then press the RETURN key. &gt;4\r\n MAIN MENU Release 137 Version V4.8\r\n SERVICE MENU\r\n\r\n\r\n CAUTION: This menu is intended for use by qualified service\r\n personnel only. Misuse of the commands could destroy data.\r\n\r\n\r\n 1 - Set test and message parameters\r\n\r\n\r\n 2 - Exercise system continuously\r\n\r\n\r\n 3 - Display the Device Menu\r\n\r\n\r\n 4 - Enter Command Line Mode\r\n\r\n\r\n Type the number; then press the RETURN key,\r\n or type 0 and press the RETURN key to return to the Main Menu. &gt;3\r\n\r\nLoaded diagnostic program for CPUA\r\n\r\nLoaded diagnostic program for MEMA\r\n\r\nLoaded diagnostic program for RQDXA\r\n\r\nLoaded diagnostic program for DZQ11A\r\n\r\nLoaded diagnostic program for TKXXA\r\n\r\nConfiguring diagnostic for CPUA\r\n\r\nConfiguring diagnostic for MEMA\r\n\r\nConfiguring diagnostic for RQDXA\r\n\r\nConfiguring diagnostic for DZQ11A\r\n\r\nConfiguring diagnostic for TKXXA\r\n\r\nThe system is ready for testing.\r\n\r\n\r\n Press the RETURN key to continue. &gt;\r\n MAIN MENU Release 137 Version V4.8\r\n SERVICE MENU\r\n DEVICE MENU\r\n\r\n\r\n This menu lets you select a device for testing.\r\n\r\n1 - CPUA - MicroVAX CPU\r\n 2 - MEMA - MicroVAX II Memory System\r\n 3 - RQDXA - Winchester\/diskette controller.\r\n 4 - DZQ11A - Asynchronous Line Controller\r\n 5 - UNKNOWN - Diagnostic not loaded.\r\n 6 - UNKNOWN - Diagnostic not loaded.\r\n 7 - UNKNOWN - Diagnostic not loaded.\r\n 8 - UNKNOWN - Diagnostic not loaded.\r\n 9 - UNKNOWN - Diagnostic not loaded.\r\n 10 - TKXXA - TK50\/TK70 CONTROLLER\r\n\r\n\r\n Type the number; then press the RETURN key,\r\n or type 0 and press the RETURN key to return to the previous menu. &gt;3\r\n MAIN MENU Release 137 Version V4.8\r\n SERVICE MENU\r\n DEVICE MENU\r\n RQDXA - Winchester\/diskette controller. MENU\r\n\r\n\r\n Testing is ENABLED\r\n\r\n1 - Enable\/disable testing for device\r\n\r\n\r\n 2 - Perform all functional tests\r\n\r\n\r\n 3 - Perform the exerciser test\r\n\r\n\r\n 4 - Display the Device Utilities Menu\r\n\r\n\r\n Type the number; then press the RETURN key,\r\n or type 0 and press the RETURN key to return to the previous menu. &gt;4\r\n\r\nConfiguring diagnostic for CPUA\r\n\r\nConfiguring diagnostic for MEMA\r\n\r\nConfiguring diagnostic for RQDXA\r\n\r\nConfiguring diagnostic for DZQ11A\r\n\r\nConfiguring diagnostic for TKXXA\r\n MAIN MENU Release 137 Version V4.8\r\n SERVICE MENU\r\n DEVICE MENU\r\n RQDXA - Winchester\/diskette controller. MENU\r\n UTILITY PROGRAMS AND TESTS MENU\r\n\r\n\r\n Utility selections are:\r\n\r\n1 - RD54, RD53, RD52, RD51, RD31, RD33 and RX33 Formatter.\r\n 2 - Utility RQDX Exerciser\r\n 3 - Customer Disk Drive Formatter.\r\n 4 - Winchester Head Parking Utility For RQDX3 Controllers.\r\n 5 - Utility Disk Scrubber Diagnostic.\r\n\r\nType the number; then press the RETURN key,\r\n or type 0 and press the RETURN key to return to the previous menu. &gt;1\r\n\r\n\r\n RUNNING A UTILITY SERVICE TEST\r\n\r\nTo halt the test at any time and return to the previous menu,\r\n press CTRL\/C by holding down the CTRL key and pressing the C key.\r\n\r\nRQDXA started.\r\nRQDXA pass 1 test number 1 started.\r\nWARNING, this utility will destroy any user data on the selected drive.\r\n\r\nDo you want to continue [YES=1,(NO=0)] ? 1\r\n\r\nWrite protect all drives not being formatted, and press RETURN to continue.\r\n\r\n\r\nDo you want to use the \"AUTOFORMAT\" mode [(Yes=1),No=0] ? 1\r\n Autosizer found:\r\n Unit Cyls UIT# Drive Name\r\n 0 1225 5 RD54\r\n 1 NON-EXISTENT\r\n 2 NON-EXISTENT\r\n 3 NON-EXISTENT\r\nMSCP Controller Model #: 19\r\n Microcode Version #: 4\r\n\r\nWhat unit do you want to format (0-0) ? 0\r\n\r\nIs this the correct unit number [(Yes=1),No=0] ?\r\nPlease type in a serial number (1 - 999999) = 213421\r\nFormat Begun -- Total number of user lbn's to format is = 311256\r\n\r\nFormat is continuing -- 1 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 29615\r\n\r\nFormat is continuing -- 2 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 59229\r\n\r\nFormat is continuing -- 3 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 88877\r\n\r\nFormat is continuing -- 4 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 118508\r\n\r\nFormat is continuing -- 5 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 148122\r\n\r\nFormat is continuing -- 6 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 177753\r\n\r\nFormat is continuing -- 7 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 207401\r\n\r\nFormat is continuing -- 8 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 237015\r\n\r\nFormat is continuing -- 9 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 266663\r\n\r\nFormat is continuing -- 10 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 296294\r\n\r\nFormat is continuing -- 11 minutes into format\r\n Pass = 1 -- Replacing defect #: 1 on head 0\r\n\r\nFormat is continuing -- 12 minutes into format\r\n Pass = 1 -- Replacing defect #: 2 on head 1\r\n\r\nFormat is continuing -- 13 minutes into format\r\n Pass = 1 -- Reading defect list on head 3\r\n\r\nFormat is continuing -- 14 minutes into format\r\n Pass = 1 -- Reading defect list on head 4\r\n\r\nFormat is continuing -- 15 minutes into format\r\n Pass = 1 -- Reading defect list on head 5\r\n\r\nFormat is continuing -- 16 minutes into format\r\n Pass = 1 -- Replacing defect #: 4 on head 6\r\n\r\nFormat is continuing -- 17 minutes into format\r\n Pass = 1 -- Replacing defect #: 7 on head 6\r\n\r\nFormat is continuing -- 18 minutes into format\r\n Pass = 1 -- Replacing defect #: 2 on head 7\r\n\r\nFormat is continuing -- 19 minutes into format\r\n Pass = 1 -- Reading defect list on head 10\r\n\r\nFormat is continuing -- 20 minutes into format\r\n Pass = 1 -- Replacing defect #: 1 on head 13\r\n\r\nFormat is continuing -- 21 minutes into format\r\n Pass = 1 -- Reading defect list on head 14\r\n\r\nFormat is continuing -- 22 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 31093\r\n\r\nFormat is continuing -- 23 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 62203\r\n\r\nFormat is continuing -- 24 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 93313\r\n\r\nFormat is continuing -- 25 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 124423\r\n\r\nFormat is continuing -- 26 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 155533\r\n\r\nFormat is continuing -- 27 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 186643\r\n\r\nFormat is continuing -- 28 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 217753\r\n\r\nFormat is continuing -- 29 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 248863\r\n\r\nFormat is continuing -- 30 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 279718\r\n\r\nFormat is continuing -- 31 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 310573\r\n\r\nFormat is continuing -- 32 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 30073\r\n\r\nFormat is continuing -- 33 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 61183\r\n\r\nFormat is continuing -- 34 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 92038\r\n\r\nFormat is continuing -- 35 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 123148\r\n\r\nFormat is continuing -- 36 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 154003\r\n\r\nFormat is continuing -- 37 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 185113\r\n\r\nFormat is continuing -- 38 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 216223\r\n\r\nFormat is continuing -- 39 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 247333\r\n\r\nFormat is continuing -- 40 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 277678\r\n\r\nFormat is continuing -- 41 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 308533\r\n\r\n\r\nFormat Summary Report:\r\n 20 Revectored LBNs.\r\n 0 Bad RBNs.\r\n 0 Bad DBNs.\r\n 0 Bad XBNS.\r\n 0 Blocks retired on check pass.\r\n\r\n\r\nThe drive has been formatted successfully.\r\nWould you like to format another unit [YES=1,(NO=0)] ?\r\n<\/pre>\n<p>So\u00a0 the first Disk is in a very good condition.<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h3>2. Disk<\/h3>\n<pre>Do you want to use the \"AUTOFORMAT\" mode [(Yes=1),No=0] ? 1\r\n Autosizer found:\r\n Unit Cyls UIT# Drive Name\r\n 0 1225 5 RD54\r\n 1 NON-EXISTENT\r\n 2 NON-EXISTENT\r\n 3 NON-EXISTENT\r\nMSCP Controller Model #: 19\r\n Microcode Version #: 4\r\n\r\nWhat unit do you want to format (0-0) ? 0\r\n\r\nIs this the correct unit number [(Yes=1),No=0] ? 1\r\nPlease type in a serial number (1 - 999999) = 123421\r\nFormat Begun -- Total number of user lbn's to format is = 311256\r\n\r\nFormat is continuing -- 1 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 29598\r\n\r\nFormat is continuing -- 2 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 59229\r\n\r\nFormat is continuing -- 3 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 88860\r\n\r\nFormat is continuing -- 4 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 118491\r\n\r\nFormat is continuing -- 5 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 148122\r\n\r\nFormat is continuing -- 6 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 177736\r\n\r\nFormat is continuing -- 7 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 207367\r\n\r\nFormat is continuing -- 8 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 236998\r\n\r\nFormat is continuing -- 9 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 266629\r\n\r\nFormat is continuing -- 10 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 296260\r\n\r\nFormat is continuing -- 11 minutes into format\r\n Pass = 1 -- Replacing defect #: 1 on head 0\r\n\r\nFormat is continuing -- 12 minutes into format\r\n Pass = 1 -- Reading defect list on head 3\r\n\r\nFormat is continuing -- 13 minutes into format\r\n Pass = 1 -- Reading defect list on head 6\r\n\r\nFormat is continuing -- 14 minutes into format\r\n Pass = 1 -- Replacing defect #: 1 on head 7\r\n\r\nFormat is continuing -- 15 minutes into format\r\n Pass = 1 -- Reading defect list on head 8\r\n\r\nFormat is continuing -- 16 minutes into format\r\n Pass = 1 -- Reading defect list on head 10\r\n\r\nFormat is continuing -- 17 minutes into format\r\n Pass = 1 -- Replacing defect #: 3 on head 11\r\n\r\nFormat is continuing -- 18 minutes into format\r\n Pass = 1 -- Replacing defect #: 1 on head 13\r\n\r\nFormat is continuing -- 19 minutes into format\r\n Pass = 1 -- Replacing defect #: 1 on head 14\r\n\r\nFormat is continuing -- 20 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 31093\r\n\r\nFormat is continuing -- 21 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 62203\r\n\r\nFormat is continuing -- 22 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 93313\r\n\r\nFormat is continuing -- 23 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 124168\r\n\r\nFormat is continuing -- 24 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 155278\r\n\r\nFormat is continuing -- 25 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 186133\r\n\r\nFormat is continuing -- 26 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 216988\r\n\r\nFormat is continuing -- 27 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 248098\r\n\r\nFormat is continuing -- 28 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 279208\r\n\r\nFormat is continuing -- 29 minutes into format\r\n Pass = 6 -- Third check pass, writing lbn #: 310318\r\n\r\nFormat is continuing -- 30 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 30073\r\n\r\nFormat is continuing -- 31 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 61183\r\n\r\nFormat is continuing -- 32 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 92038\r\n\r\nFormat is continuing -- 33 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 122638\r\n\r\nFormat is continuing -- 34 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 153493\r\n\r\nFormat is continuing -- 35 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 184093\r\n\r\nFormat is continuing -- 36 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 214693\r\n\r\nFormat is continuing -- 37 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 245803\r\n\r\nFormat is continuing -- 38 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 276913\r\n\r\nFormat is continuing -- 39 minutes into format\r\n Pass = 7 -- Third check pass, reading lbn #: 308023\r\n\r\n\r\nFormat Summary Report:\r\n 16 Revectored LBNs.\r\n 0 Bad RBNs.\r\n 0 Bad DBNs.\r\n 0 Bad XBNS.\r\n 0 Blocks retired on check pass.\r\n\r\n\r\nThe drive has been formatted successfully.\r\nWould you like to format another unit [YES=1,(NO=0)] ?\r\n\r\n<\/pre>\n<hr \/>\n<p>&nbsp;<\/p>\n<h3>3. Disk<\/h3>\n<p>&nbsp;<\/p>\n<pre>\r\nRQDXA started.\r\nRQDXA pass 1 test number 1 started.\r\nWARNING, this utility will destroy any user data on the selected drive.\r\n\r\nDo you want to continue [YES=1,(NO=0)] ? 1\r\n\r\nWrite protect all drives not being formatted, and press RETURN to continue.\r\n\r\n\r\nDo you want to use the \"AUTOFORMAT\" mode [(Yes=1),No=0] ? 1\r\n Autosizer found:\r\n Unit Cyls UIT# Drive Name\r\n 0 1225 5 RD54\r\n 1 NON-EXISTENT\r\n 2 NON-EXISTENT\r\n 3 NON-EXISTENT\r\nMSCP Controller Model #: 19\r\n Microcode Version #: 4\r\n\r\nWhat unit do you want to format (0-0) ? 0\r\n\r\nIs this the correct unit number [(Yes=1),No=0] ? 1\r\nPlease type in a serial number (1 - 999999) = 321413\r\nFormat Begun -- Total number of user lbn's to format is = 311256\r\n\r\nFormat is continuing -- 1 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 29598\r\n\r\nFormat is continuing -- 2 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 59229\r\n\r\nFormat is continuing -- 3 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 88843\r\n\r\nFormat is continuing -- 4 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 118474\r\n\r\nFormat is continuing -- 5 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 148105\r\n\r\nFormat is continuing -- 6 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 177719\r\n\r\nFormat is continuing -- 7 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 207333\r\n\r\nFormat is continuing -- 8 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 236964\r\n\r\nFormat is continuing -- 9 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 266595\r\n\r\nFormat is continuing -- 10 minutes into format\r\n Pass = 0 -- Formatting tracks, lbn #: 296209\r\nThe failure could have been caused by any of the following.\r\n\r\n. The drive is offline.\r\n . The drive is write protected.\r\n . The drive is dead.\r\n . Bad block information should not have been specified.\r\n . The cables going to the drive are not making good contact.\r\n . The drive select switches are set up wrong\r\n . A non existent drive has been specified.\r\n\r\nController has reported an error in the FORMAT program.\r\n\r\n<\/pre>\n<hr \/>\n<p>OK, this one has obviously some defect.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Today I have reviewed a part of my DEC RD54 Drives, and have started to inventory and Format them, to see if they are still in working condition. I use always my MVII with an RQDX3 Controller and the DEC MDM Diagnostics. (not the Customer version) You can also use a MicroVAX2000, as he has <a href='https:\/\/www.pdp-11.de\/index.php\/dec-devices\/dec-rd54-maxtor-xt2190\/' class='excerpt-more'>[&#8230;]<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":492,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1635","page","type-page","status-publish","hentry","odd","post-seq-1","post-parity-odd","meta-position-left-outer-pullout","fix"],"_links":{"self":[{"href":"https:\/\/www.pdp-11.de\/index.php\/wp-json\/wp\/v2\/pages\/1635","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pdp-11.de\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.pdp-11.de\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.pdp-11.de\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pdp-11.de\/index.php\/wp-json\/wp\/v2\/comments?post=1635"}],"version-history":[{"count":8,"href":"https:\/\/www.pdp-11.de\/index.php\/wp-json\/wp\/v2\/pages\/1635\/revisions"}],"predecessor-version":[{"id":1645,"href":"https:\/\/www.pdp-11.de\/index.php\/wp-json\/wp\/v2\/pages\/1635\/revisions\/1645"}],"up":[{"embeddable":true,"href":"https:\/\/www.pdp-11.de\/index.php\/wp-json\/wp\/v2\/pages\/492"}],"wp:attachment":[{"href":"https:\/\/www.pdp-11.de\/index.php\/wp-json\/wp\/v2\/media?parent=1635"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}